Hepatitis C virus antibody/antigen
Description:
The assay is performed on two platforms:
1) For routine testing, Bio-Rad Monolisa HCV Ag/Ab ULTRA EIA is an enzyme immunoassay for the detection of HCV infections, based on the detection of HCV capsid antigen and HCV-specific antibodies in serum or plasma.
2) For urgent testing the Abbott Architect platform is used. This detects HCV antibody only.
1) For routine testing, Bio-Rad Monolisa HCV Ag/Ab ULTRA EIA is an enzyme immunoassay for the detection of HCV infections, based on the detection of HCV capsid antigen and HCV-specific antibodies in serum or plasma.
2) For urgent testing the Abbott Architect platform is used. This detects HCV antibody only.
Clinical details:
All positive or indeterminate results are clarified by HCV RNA quantitative assay for HCV viraemia.
Units:
Positive/Negative/Indeterminate
Department:
Location:
Sample type and Volume required:
6-8 ml serum or plasma
Turnaround time:
2 days
Contacts:
South London Specialist Virology Centre
Results: 02032996155 Medical Advice: 02032996298
King's College Hospital
Cheyne Wing, 2nd Floor (opposite Liver ITU)
Denmark Hill
London SE5 9RS
DX address: South London (PHL) Kings DX 6570200 Peckham 90SE
Cheyne Wing, 2nd Floor (opposite Liver ITU)
Denmark Hill
London SE5 9RS
DX address: South London (PHL) Kings DX 6570200 Peckham 90SE
Laboratory: